KM9 SeRIeS VaRIaTIONS
INDUSTRIAL COMBUSTION ANALYZERS
• Flueprobeassembly........................(KMCP10)
ACadapter..............................(KMCU900/110)
Replacementparticlefilter..................(16345)
Watertrapassembly....................... (WT900/2)
Largecorduracase
Instructionmanual
KM900PLUS
Industrial Combustion
Analyzer
Measures
• Oxygen(O²)0~20.9%
• CarbonMonoxide(CO)0~10,000ppm
(H²CompensatedandNOXFiltered)
FlueTemperature32~1112˚F
Calculates
• Combustionefficiency,carbondioxide
(CO²),netstacktemperature,fluelosses,
excessair,CO/CO²ratio,poisonindex
• Expandablecapability,addupto
twoadditionaltoxicgassensors
• 150Memorylocationsfortestresults
• Infraredprinterport
• Large4-linedisplay
• Long-life6VsealedgelcellwithACcharger
PART # Base Model Sensor Configuration Notes
KM940CON KM940 O2 CO NO1 CalculatedNOX
KM940COS KM940 O2 CO SO2
KM940CONOX KM940 O2 CO NO1 NO2 TrueNOX
KM940CONS KM940 O2 CO NO1 SO2 CalculatedNOX+SO2
KM940CO% KM940 O2 CO(HiRange)
KM900CON KM900PLUS O2 CO NO1 CalculatedNOX
KM900COS KM900PLUS O2 CO SO2
KM900CONOX KM900PLUS O2 CO NO1 NO2 TrueNOX
KM900CONS KM900PLUS O2 CO NO1 SO2 CalculatedNOX+SO2
Gas Measurement Resolution Accuracy Range
Carbon Monoxide high range (CO%) 0.01% ±5%readingfrom0.1%to10% 0~10%
Nitric Oxide (NO1) 1ppm ±5ppm<100ppm±5%>100ppm 0~5000ppm
Nitric Oxide (NO1) low range 1ppm ±2ppm<30ppm±5ppm<30ppm 0~100ppm
Nitrogen Dioxide (NO2) 1ppm ±5ppm<100ppm±10ppm<500ppm±5%>500ppm 0~1000ppm
Sulfur Dioxide (SO2) 1ppm ±5ppm<100ppm±5%>100ppm 0~5000ppm
Visit us at www.TestEquipmentDepot.com