CO91 Carbon Monoxide Analyzer
Copyright © 2007 UEi Specifications are subject to change without notice. L623 Z 1/07
Distributed By:
1-800-547-5740 • Fax: (503) 643-6322
www.ueitest.com • Email: [email protected]
IN CANADA
Vancouver: Phone: 1-877-475-0648 • (604) 278-4511 • Fax: (604) 278-8299
Toronto: Phone: 1-877-475-0648 • Fax: (905) 238-5117
IN EUROPE
Phone: +44 1707 375550 • Fax: +44 1707 393277
The CO91 is used to check ambient CO levels, find leaks
along flue pipes, or measure CO concentration in flue gas from
furnaces or residential combustion appliances. With a link to the
optional infrared printer, results can be printed to document test
results, including the date and time. Perform adjustments to the
appliance, and then recall the highest level of CO with the CO
Max function. With the temperature function you are able to test
register outlet temperatures, or monitor stack gas temperature.
The CO91
has the following features:
Powered by 4 AA alkaline batteries
Three year limited warranty (two years on sensor)
Accessories included
AC75 - soft carrying case
ATT100 temperature probe
Parameter Resolution Accuracy Range
Temperature Measurement
Temperature: 1.0˚F/C ±5.0˚F (2.0˚C) 32-1112˚F
±0.3% reading 0-600˚C
Gas Measurement
Carbon Monoxide 1 ppm ±10 ppm<100 ppm
*1
0-1999 ppm
±5% of rdg>100 ppm
Dimensions
Weight 2.2lb / 1 kg
Handset 7.9” x 1.8” x 3.5” (200mm x 45mm x 90mm)
Probe L 11.8” x Dia .25”/7.8” long stainless steel shaft
(300mm x 6mm/200mm)
Ambient Operating Range 32˚ to 104˚F (0˚ to +40˚C)
10% to 90% RH non-condensing
Battery Life 4 “AA” cells
>8 hours using Alkaline AA cells
AC adapter (optional) Input: 110V AC
Output: 9V DC regulated 500mA minimum
*1 Using dry gases at Standard Temperature and Pressure (STP)
Important Numbers To Remember:
• 9 PPM Max prolonged exposure (ASHRAE standard)
• 35 PPM Max exposure for 8 hr work day (OSHA)
• 800 PPM Death within 2 to 3 hrs
• 12,800 PPM Death within 1-3 minutes
Specifications